Large amounts of water are currently being used in the energy sector. For assessing long-term freshwater sustainability, MESSAGE has been adapted to quantify the impact of energy system transformations on water.  
Large amounts of water are currently being used in the energy sector. For assessing long-term freshwater sustainability, MESSAGE has been adapted to quantify the impact of energy system transformations on water.  


The majority of energy sector freshwater withdrawal occurs in the steam-cycle and cooling systems related to thermoelectric power plants. Once through and closed-loop cooling technologies are distinguished in the model. In the following the differences between these two technologies are presented:
The majority of energy sector freshwater withdrawal occurs in the steam-cycle and cooling systems related to thermoelectric power plants. The model distinguishes between two different water-cooling technologies, but also a technology only using air for cooling purposes, which  provide an opportunity to reduce energy system reliance on water. The different technologies that are therefore distinguished in the model are:


Once-through cooling technology - water is passed through the cooling system once, and then returned to its source.  
*Once-through cooling technology: water is passed through the cooling system once and then returned to its source.  
Closedloop systems - water that is withdrawn is re-circulated.
*Closed-loop cooling technology: water that is withdrawn is re-circulated.
*Air-cooling technology: instead of water, air is used for cooling purposes.


The water source (fresh or saline) is further distinguished across technologies. Also air-cooled systems are considered, which provide an opportunity to reduce energy system reliance on water. The choice of model formulation enables consistent representation of water use across power plant types and incorporates water impacts of heat-rate improvements due to anticipated long-term technological change. Moreover, the approach enables analysis of thermal water pollution from once-through cooled thermal power plants by allowing quantification of the heat energy embodied in cooling system effluents.
Further, the water source is distinguished across technologies between fresh or saline.  


(Fricko et al, 2016[[CiteRef::MSG-GLB_fricko_energy_2016]])
This choice of model formulation enables consistent representation of water use across power plant types and incorporates water impacts of heat-rate improvements due to anticipated long-term technological change. Moreover, the approach enables analysis of thermal water pollution from once-through cooled thermal power plants by allowing quantification of the heat energy embodied in cooling system effluents.
 
When applied to a broad range of climate mitigation scenarios that aim for 2 degrees Celsius, the results show a wide range of water implications across scenarios. Global demand of freshwater is expected to grow in all 2 degree scenarios due to rapidly growing electricity demand in many developing countries as a result of and the prevalence of freshwater-cooled thermal power generation. However, a shift to water-efficient cooling technologies can significantly reduce the use of water within the energy sector by reducing the freshwater withdrawals and thermal pollution related to thermoelectric power production. Further, controlling demand is another strategy that can reduce the water use, and further, it provides more flexibility in terms of cooling technology choices for thermoelectric power plants. Therefore, an integrated approach, using both technology adaptation and demand control, is seen as the most effective and flexible approach to reducing water demand in the energy sector. (Fricko et al, 2016a[[CiteRef::MSG-GLB_fricko_energy_2016]])
 
<xr id="fig:MESSAGE-GLOBIOM_water1"/> presents the impact of water usage across different 2 degree scenarios from the Global Energy Assessment, and how adopting technologies can help reduce the water demand.
 
<div style=" overflow: auto;">
<figure id="fig:MESSAGE-GLOBIOM_water1">
[[File:Fricko et al image1.jpg|left|900px|thumb|<caption>Global water impacts across the 2 °C and reference scenarios for the two thermal power plant cooling technology cases: (A) baseline cooling technologies; and (B) adapt cooling technologies. Individual scenario results are illustrated for a subset of climate change mitigation and reference scenarios with intermediate energy demand (GEA-Mix). The full range of water impacts associated with all technology scenarios are illustrated for each energy demand assumption (GEA-Efficiency, GEA-Mix, and GEA-Supply). The additional range resulting from the maximum and minimum reported water intensity coefficients are indicated by gray lines. (Fricko et al., 2016a)</caption>]] [[CiteRef::MSG-GLB_fricko_energy_2016]]
</figure>
</div>

Revision as of 09:24, 21 October 2016

Model Documentation - MESSAGE-GLOBIOM

Corresponding documentation
Previous versions
Model information
Model link
Institution International Institute for Applied Systems Analysis (IIASA), Austria, http://data.ene.iiasa.ac.at.
Solution concept General equilibrium (closed economy)
Solution method Optimization
Anticipation

Large amounts of water are currently being used in the energy sector. For assessing long-term freshwater sustainability, MESSAGE has been adapted to quantify the impact of energy system transformations on water.

The majority of energy sector freshwater withdrawal occurs in the steam-cycle and cooling systems related to thermoelectric power plants. The model distinguishes between two different water-cooling technologies, but also a technology only using air for cooling purposes, which provide an opportunity to reduce energy system reliance on water. The different technologies that are therefore distinguished in the model are:

  • Once-through cooling technology: water is passed through the cooling system once and then returned to its source.
  • Closed-loop cooling technology: water that is withdrawn is re-circulated.
  • Air-cooling technology: instead of water, air is used for cooling purposes.

Further, the water source is distinguished across technologies between fresh or saline.

This choice of model formulation enables consistent representation of water use across power plant types and incorporates water impacts of heat-rate improvements due to anticipated long-term technological change. Moreover, the approach enables analysis of thermal water pollution from once-through cooled thermal power plants by allowing quantification of the heat energy embodied in cooling system effluents.

When applied to a broad range of climate mitigation scenarios that aim for 2 degrees Celsius, the results show a wide range of water implications across scenarios. Global demand of freshwater is expected to grow in all 2 degree scenarios due to rapidly growing electricity demand in many developing countries as a result of and the prevalence of freshwater-cooled thermal power generation. However, a shift to water-efficient cooling technologies can significantly reduce the use of water within the energy sector by reducing the freshwater withdrawals and thermal pollution related to thermoelectric power production. Further, controlling demand is another strategy that can reduce the water use, and further, it provides more flexibility in terms of cooling technology choices for thermoelectric power plants. Therefore, an integrated approach, using both technology adaptation and demand control, is seen as the most effective and flexible approach to reducing water demand in the energy sector. (Fricko et al, 2016aMSG-GLB_fricko_energy_2016)

<xr id="fig:MESSAGE-GLOBIOM_water1"/> presents the impact of water usage across different 2 degree scenarios from the Global Energy Assessment, and how adopting technologies can help reduce the water demand.

<figure id="fig:MESSAGE-GLOBIOM_water1">

Global water impacts across the 2 °C and reference scenarios for the two thermal power plant cooling technology cases: (A) baseline cooling technologies; and (B) adapt cooling technologies. Individual scenario results are illustrated for a subset of climate change mitigation and reference scenarios with intermediate energy demand (GEA-Mix). The full range of water impacts associated with all technology scenarios are illustrated for each energy demand assumption (GEA-Efficiency, GEA-Mix, and GEA-Supply). The additional range resulting from the maximum and minimum reported water intensity coefficients are indicated by gray lines. (Fricko et al., 2016a)
MSG-GLB_fricko_energy_2016

</figure>